Catalogue
We understoodflux-cored wire (FCW)
42 materials
To order · price and lead time in the quote
Flux-cored wire · Carbon and low-alloy steel 21 materials
| Product | Standard | Gas / self-shielded | Request |
|---|---|---|---|
| ELCOR M 70 FCWGedik | AWSE70C-6MEN ISOT 46 4 M M 3 | Requires shielding gas | |
| ELCOR B 70 - ARM FCWGedik | AWSE70T-5MEN ISOT 42 A Z B M 3 | Requires shielding gas | |
| ELCOR B 70 FCWGedik | AWSE70T-5MJEN ISOT 42 4 B M 3 H5 | Requires shielding gas | |
| ELCOR MR 70 FCWGedik | AWSE70T-9CJ H8EN ISOT 42 4 R C3 H10 | Requires shielding gas | |
| DT-BF 31 FCWDratec | AWSE70T15-M21A4-CS1-H4, E70T5-C1A4-CS1-H4EN ISOT 46 4 B M 3 H5 / T 42 4 B C 3 H5 | Requires shielding gas | |
| DT-MF 10 FCWDratec | AWSE70T15-M21A8-CS1-H4, E70T15-C1A6-CS1-H4EN ISOT 46 6 M M 1 H5 / T 42 5 M C 1 H5 | Requires shielding gas | |
| ELCOR R 71 FCWGedik | AWSE71T-1C-JEN ISOT 42 4 P C 1 H5 | Requires shielding gas | |
| ELCOR R 71 CM FCWGedik | AWSE71T-1MEN ISOT 46 2 P M 1 | Requires shielding gas | |
| DT-RF 14 FCWDratec | AWSE71T1-M21AP5-CS2-DH4, E71T1-C1A4-CS2-DH4EN ISOT 46 4 P M 1 H5 / T 46 2 P C 1 H5 | Requires shielding gas | |
| ELCOR M 80 Ni FCWGedik | AWSE 80 C Ni 1EN ISOT 50 4 M M 3 | Requires shielding gas | |
| ELCOR M Mo FCWGedik | AWSE80T1-A1MEN ISOT 46 2 Mo M M 3 | Requires shielding gas | |
| ELCOR R Mo FCWGedik | AWSE81T1-A1CEN ISOT 46 2 Mo R C 2 | Requires shielding gas | |
| ELCOR R CrMo1 FCWGedik | AWSE81T1-B2CEN ISOT CrMo1 R C 2 | Requires shielding gas | |
| ELCOR R 81 Ni FCWGedik | AWSE81T1-Ni1CEN ISOT 46 4 1Ni P C 1 | Requires shielding gas | |
| ELCOR R 81 NiCu FCWGedik | AWSE81T1-W2CEN ISOT 55 3 T1-1CA-NCC1 | Requires shielding gas | |
| ELCOR R CrMo 2 FCWGedik | AWSE91T1-B3C/B3MEN ISOT CrMo2 R C 1/T CrMo2 R M 1 | Requires shielding gas | |
| ELCOR R 91 FCWGedik | AWSE91T1-K2CJEN ISOT 62 4 Mn 1.5 Ni PC 1 | Requires shielding gas | |
| DT-MF 15 FCWDratec | AWSE110T15-M21A8-K4-H4EN ISOT 69 6 Mn2NiCrMo MM 1 H5 | Requires shielding gas | |
| DT-MF 35 FCWDratec | AWSE80C-GM H4EN ISOT 46 2 Mo MM 1 H5 | Requires shielding gas | |
| ELCOR R 110 FCWGedik | AWSE111T1-GCEN ISOT 69 4 Mn2.5Ni P C 1 | Requires shielding gas | |
| DT-FD2-O FCWDratec | AWSE 71 TGSEN ISOT 42 Z W NO 1 H5 | Self-shielded (open arc) |
ELCOR M 70 FCWGedik
- Standard
- AWSE70C-6MEN ISOT 46 4 M M 3
- Gas / self-shielded
- Requires shielding gas
ELCOR B 70 - ARM FCWGedik
- Standard
- AWSE70T-5MEN ISOT 42 A Z B M 3
- Gas / self-shielded
- Requires shielding gas
ELCOR B 70 FCWGedik
- Standard
- AWSE70T-5MJEN ISOT 42 4 B M 3 H5
- Gas / self-shielded
- Requires shielding gas
ELCOR MR 70 FCWGedik
- Standard
- AWSE70T-9CJ H8EN ISOT 42 4 R C3 H10
- Gas / self-shielded
- Requires shielding gas
DT-BF 31 FCWDratec
- Standard
- AWSE70T15-M21A4-CS1-H4, E70T5-C1A4-CS1-H4EN ISOT 46 4 B M 3 H5 / T 42 4 B C 3 H5
- Gas / self-shielded
- Requires shielding gas
DT-MF 10 FCWDratec
- Standard
- AWSE70T15-M21A8-CS1-H4, E70T15-C1A6-CS1-H4EN ISOT 46 6 M M 1 H5 / T 42 5 M C 1 H5
- Gas / self-shielded
- Requires shielding gas
ELCOR R 71 FCWGedik
- Standard
- AWSE71T-1C-JEN ISOT 42 4 P C 1 H5
- Gas / self-shielded
- Requires shielding gas
ELCOR R 71 CM FCWGedik
- Standard
- AWSE71T-1MEN ISOT 46 2 P M 1
- Gas / self-shielded
- Requires shielding gas
DT-RF 14 FCWDratec
- Standard
- AWSE71T1-M21AP5-CS2-DH4, E71T1-C1A4-CS2-DH4EN ISOT 46 4 P M 1 H5 / T 46 2 P C 1 H5
- Gas / self-shielded
- Requires shielding gas
ELCOR M 80 Ni FCWGedik
- Standard
- AWSE 80 C Ni 1EN ISOT 50 4 M M 3
- Gas / self-shielded
- Requires shielding gas
ELCOR M Mo FCWGedik
- Standard
- AWSE80T1-A1MEN ISOT 46 2 Mo M M 3
- Gas / self-shielded
- Requires shielding gas
ELCOR R Mo FCWGedik
- Standard
- AWSE81T1-A1CEN ISOT 46 2 Mo R C 2
- Gas / self-shielded
- Requires shielding gas
ELCOR R CrMo1 FCWGedik
- Standard
- AWSE81T1-B2CEN ISOT CrMo1 R C 2
- Gas / self-shielded
- Requires shielding gas
ELCOR R 81 Ni FCWGedik
- Standard
- AWSE81T1-Ni1CEN ISOT 46 4 1Ni P C 1
- Gas / self-shielded
- Requires shielding gas
ELCOR R 81 NiCu FCWGedik
- Standard
- AWSE81T1-W2CEN ISOT 55 3 T1-1CA-NCC1
- Gas / self-shielded
- Requires shielding gas
ELCOR R CrMo 2 FCWGedik
- Standard
- AWSE91T1-B3C/B3MEN ISOT CrMo2 R C 1/T CrMo2 R M 1
- Gas / self-shielded
- Requires shielding gas
ELCOR R 91 FCWGedik
- Standard
- AWSE91T1-K2CJEN ISOT 62 4 Mn 1.5 Ni PC 1
- Gas / self-shielded
- Requires shielding gas
DT-MF 15 FCWDratec
- Standard
- AWSE110T15-M21A8-K4-H4EN ISOT 69 6 Mn2NiCrMo MM 1 H5
- Gas / self-shielded
- Requires shielding gas
DT-MF 35 FCWDratec
- Standard
- AWSE80C-GM H4EN ISOT 46 2 Mo MM 1 H5
- Gas / self-shielded
- Requires shielding gas
ELCOR R 110 FCWGedik
- Standard
- AWSE111T1-GCEN ISOT 69 4 Mn2.5Ni P C 1
- Gas / self-shielded
- Requires shielding gas
DT-FD2-O FCWDratec
- Standard
- AWSE 71 TGSEN ISOT 42 Z W NO 1 H5
- Gas / self-shielded
- Self-shielded (open arc)
Flux-cored wire · Stainless 8 materials
| Product | Standard | Gas / self-shielded | Request |
|---|---|---|---|
| DT-308 F FCWDratec | AWSE 308 L T-0-1/4EN ISOT 19 9 L R C/M 3 | Requires shielding gas | |
| ELOXCOR S 308 L FCWGedik | AWSE308LT1-1/-4EN ISOT 19 9 L P M21/C1 1 | Requires shielding gas | |
| DT-309 F FCWDratec | AWSE309LT0-1/-4EN ISOT 23 12 L R C/M 3 | Requires shielding gas | |
| ELOXCOR S 309 L FCWGedik | AWSE309LT1-1/-4EN ISOT 23 12 L P M21/C1 1 | Requires shielding gas | |
| DT-316 F FCWDratec | AWSE316LT0-1/-4EN ISOT 19 12 3 L R C/M 3 | Requires shielding gas | |
| ELOXCOR S 316 L FCWGedik | AWSE316LT1-1/-4EN ISOT Z 19 12 3 L P M21/C1 1 | Requires shielding gas | |
| ELOXCOR S 2209 FCWGedik | AWSE2209T1-1/-4EN ISOT 22 9 3 N L P M21/C 1 1 | Requires shielding gas | |
| ELOXCOR S 307 FCWGedik | AWSE307T1-1/-4 (mod.)EN ISOT 18 8 Mn P M21/C1 1 | Requires shielding gas |
DT-308 F FCWDratec
- Standard
- AWSE 308 L T-0-1/4EN ISOT 19 9 L R C/M 3
- Gas / self-shielded
- Requires shielding gas
ELOXCOR S 308 L FCWGedik
- Standard
- AWSE308LT1-1/-4EN ISOT 19 9 L P M21/C1 1
- Gas / self-shielded
- Requires shielding gas
DT-309 F FCWDratec
- Standard
- AWSE309LT0-1/-4EN ISOT 23 12 L R C/M 3
- Gas / self-shielded
- Requires shielding gas
ELOXCOR S 309 L FCWGedik
- Standard
- AWSE309LT1-1/-4EN ISOT 23 12 L P M21/C1 1
- Gas / self-shielded
- Requires shielding gas
DT-316 F FCWDratec
- Standard
- AWSE316LT0-1/-4EN ISOT 19 12 3 L R C/M 3
- Gas / self-shielded
- Requires shielding gas
ELOXCOR S 316 L FCWGedik
- Standard
- AWSE316LT1-1/-4EN ISOT Z 19 12 3 L P M21/C1 1
- Gas / self-shielded
- Requires shielding gas
ELOXCOR S 2209 FCWGedik
- Standard
- AWSE2209T1-1/-4EN ISOT 22 9 3 N L P M21/C 1 1
- Gas / self-shielded
- Requires shielding gas
ELOXCOR S 307 FCWGedik
- Standard
- AWSE307T1-1/-4 (mod.)EN ISOT 18 8 Mn P M21/C1 1
- Gas / self-shielded
- Requires shielding gas
Flux-cored wire · Hardfacing 13 materials
| Product | Standard | Gas / self-shielded | Request |
|---|---|---|---|
| HARDCOR 300 G FCWGedik | 300 HBEN 14700T Fe1 | — | |
| HARDCOR KST 45 FCWGedik | 39–41 HRCEN 14700T Z Fe3 | Requires shielding gas | |
| HARDCOR 50 G FCWGedik | 48–50 HRCEN 14700T Z Fe8 | Requires shielding gas | |
| HARDCOR KST 55 FCWGedik | 52–57 HRCEN 14700T Z Fe3 | Requires shielding gas | |
| HARDCOR M 55 FCWGedik | 53–56 HRCEN 14700T Fe8 | Requires shielding gas | |
| DIN 8555 MF 6-GF-60-GP | |||
| HARDCOR 60 G FCWGedik | 57–62 HRCEN 14700T Fe8 | Requires shielding gas | |
| HARDCOR 600 G FCWGedik | 600 HBEN 14700T Fe6 | Requires shielding gas | |
| HARDCOR M 600 G FCWGedik | 600 HBDIN 8555MF 6-GF-60-GP | Requires shielding gas | |
| HARDCOR 600 GS FCWGedik | 56 HRCEN 14700T Fe6 | Requires shielding gas | |
| HARDCOR 14 Mn G FCWGedik | 175–225 HBEN 14700T Fe9 | Requires shielding gas | |
| HARDCOR COBALT 6 FCWGedik | 40–43 HRCEN 14700T Co2 | Requires shielding gas | |
| HARDCOR COBALT 12 FCWGedik | 48–50 HRCEN 14700T Co3 | Requires shielding gas | |
| DT-SG 600 F FCWDratec | 57–62 HRCEN 14700T Fe6 | Requires shielding gas | |
HARDCOR 300 G FCWGedik
- Standard
- 300 HBEN 14700T Fe1
- Gas / self-shielded
- —
HARDCOR KST 45 FCWGedik
- Standard
- 39–41 HRCEN 14700T Z Fe3
- Gas / self-shielded
- Requires shielding gas
HARDCOR 50 G FCWGedik
- Standard
- 48–50 HRCEN 14700T Z Fe8
- Gas / self-shielded
- Requires shielding gas
HARDCOR KST 55 FCWGedik
- Standard
- 52–57 HRCEN 14700T Z Fe3
- Gas / self-shielded
- Requires shielding gas
HARDCOR M 55 FCWGedik
- Standard
- 53–56 HRCEN 14700T Fe8
- Gas / self-shielded
- Requires shielding gas
DIN 8555 MF 6-GF-60-GP
HARDCOR 60 G FCWGedik
- Standard
- 57–62 HRCEN 14700T Fe8
- Gas / self-shielded
- Requires shielding gas
HARDCOR 600 G FCWGedik
- Standard
- 600 HBEN 14700T Fe6
- Gas / self-shielded
- Requires shielding gas
HARDCOR M 600 G FCWGedik
- Standard
- 600 HBDIN 8555MF 6-GF-60-GP
- Gas / self-shielded
- Requires shielding gas
HARDCOR 600 GS FCWGedik
- Standard
- 56 HRCEN 14700T Fe6
- Gas / self-shielded
- Requires shielding gas
HARDCOR 14 Mn G FCWGedik
- Standard
- 175–225 HBEN 14700T Fe9
- Gas / self-shielded
- Requires shielding gas
HARDCOR COBALT 6 FCWGedik
- Standard
- 40–43 HRCEN 14700T Co2
- Gas / self-shielded
- Requires shielding gas
HARDCOR COBALT 12 FCWGedik
- Standard
- 48–50 HRCEN 14700T Co3
- Gas / self-shielded
- Requires shielding gas
DT-SG 600 F FCWDratec
- Standard
- 57–62 HRCEN 14700T Fe6
- Gas / self-shielded
- Requires shielding gas