We open on 1 January 2027. Until then we are not accepting registrations or requests.
Datasheetas published in the maker's catalogueCross-referencesacross makers and AWS / EN ISO classesDeliverySpain and PortugalESPTEN
FERVEO
Basket
Gedik · Carbon steels

ELCOR M 70 FCW — E 70 C-6 M

flux-cored wire (FCW)

Choose the size

  • Ø 1.2 mm · BS 300
    ≈ 15 kg
  • Ø 1.6 mm · BS 300
    ≈ 15 kg
To order · price and lead time in the quote

We reply within 1 working day.

How much filler metal do I need?With this product's data: 138 · η 0.90–0.98
Thickness of the plates to be joinedref. 1.3: 3 < t ≤ 10
Sum of all identical welds

4.62–6.81 kg

of ELCOR M 70 FCW for 10 m of weld

1 pack of 15 kg

Calculated with: η 0.90–0.98: typical value for process 138 · preparation per EN ISO 9692-1 · EN ISO 5817 level C

See the full calculation →

Field of application

  • Metal-cored wire for butt and fillet welds
  • Less spatter than solid wires; in spray transfer it works over a wider current range
  • High deposition rate
  • Better arc stability than solid wires
  • Shielding gas: M21

Base metals

S235JRS275JRS235J2G3-S355J2G3P 235T1-P355T1P235T2-P355T2L210NB-L415NBL290MB-L415MBP235G1THP255G1THP235GH-P355GHP295GHS235JRS1-S235J4SS315G1S-S355G3SS255N-S420NS255NL-S355NLGE200-GE260X42-X60
PositionsPA flat PB horizontal-vertical PC horizontal
PolarityDC+
Shielding gasM21

Classification and approvals

Classification

AWS classE 70 C-6 M
EN ISO classT 46 4 M M 3

Approvals

  • ELCOR M 70 (M21): BV, ABS, CE, SEPRO
According to the Gedik 2023 catalogue; validity is confirmed with the order

Composition and properties

Chemical composition of the weld metal

C0.05
Mn1.60
Si0.65
Values in mass %.

Mechanical properties

as welded
Yield strength (Rp0.2)min. 460 MPa
Tensile strength (Rm)530–650 MPa
Elongation (A5)min. 22 %
Impact energy (KV)min. 47 J (−40 °C)

How to weld

Process

ShieldingRequires shielding gas
FERVEO guidance
By problem
Structural steels
Alternatives in the catalogue
Similar
ISO 17632-A: same strength (46), equal or better toughness (47 J at −40 °C), same cored-wire type (M)
ProductClassRmAvailability
DT-MF 10 FCWDratecT 46 6 M M 1 H5530–680 MPaTo order · price and lead time in the quote