We open on 1 January 2027. Until then we are not accepting registrations or requests.
Datasheetas published in the maker's catalogueCross-referencesacross makers and AWS / EN ISO classesDeliverySpain and PortugalESPTEN
FERVEO
Basket
Dratec · Carbon steels

DT-BF 31 FCW — E70T15-M21A4-CS1-H4, E70T5-C1A4-CS1-H4

flux-cored wire (FCW)

Choose the size

  • Ø 1.2 mm
    ≈ 15 kg
  • Ø 1.6 mm
    ≈ 15 kg

Supply programme: spools on request D100 (0.5–1 kg), D200 (2–5 kg), K300 (15–20 kg)

To order · price and lead time in the quote

We reply within 1 working day.

How much filler metal do I need?With this product's data: 136 · η 0.88–0.90
Thickness of the plates to be joinedref. 1.3: 3 < t ≤ 10
Sum of all identical welds

5.03–6.97 kg

of DT-BF 31 FCW for 10 m of weld

1 pack of ≈ 15 kg

Calculated with: η 0.88–0.90 — from the datasheet · preparation per EN ISO 9692-1 · EN ISO 5817 level C

See the full calculation →
Do I need to preheat?With this product's data: H5
Thickness of the thickest part in the jointmethod B: d from 10 to 90 mm

105 °C

Minimum preheat and minimum interpass temperature

EN 1011-2, annex C, method B · rounded up to 5 °C

✓ Within the range of method B.

Calculated with: HD 5 ml/100 g from this product's class H5 · 136 — gas-shielded flux-cored: 26 V, 220 A, 30 cm/min

See the full calculation →

Field of application

Flux-cored wire with highly basic slag, for welds in which high mechanical quality values have to be reached. Spatter-free, with a very easily removable slag. Suitable for high-carbon steels. Buffer layers; recovery >88 %

Base metals

St 37.0-St 52.0HI-HII17Mn4StE 255-StE 460
PositionsPA flat PB horizontal-vertical
PolarityDC+
Shielding gasM2, M3, C

Classification and approvals

Classification

AWS classE70T15-M21A4-CS1-H4, E70T5-C1A4-CS1-H4
EN ISO classT46 4 B M 3 H5 / T42 4 B C 3 H5

Approvals

  • TÜV, DB, CE
According to the Dratec 2025 catalogue; validity is confirmed with the order

Composition and properties

Chemical composition of the wire

C0.06
Mn1.55
Si0.50
Values in mass %.

Mechanical properties

guide values, with mixed gas
Yield strength (Rp0.2)min. 460 MPa
Tensile strength (Rm)530–680 MPa
Elongation (A5)min. 20 %

How to weld

Process

ShieldingRequires shielding gas
Recovery> 88 %
FERVEO guidance
By problem
Structural steels
Alternatives in the catalogue
Similar
ISO 17632-A: same strength (42), equal or better toughness (47 J at −40 °C), same cored-wire type (B)
ProductClassAvailability
ELCOR B 70 FCWGedikT 42 4 B M 3 H5To order · price and lead time in the quote