We open on 1 January 2027. Until then we are not accepting registrations or requests.
Datasheetas published in the maker's catalogueCross-referencesacross makers and AWS / EN ISO classesDeliverySpain and PortugalESPTEN
FERVEO
Basket
Gedik · Carbon steels

ELCOR MR 70 FCW — E 70 T-9 C J H 8

flux-cored wire (FCW)

Choose the size

  • Ø 1.2 mm · BS 300
    ≈ 15 kg
To order · price and lead time in the quote

We reply within 1 working day.

How much filler metal do I need?With this product's data: 136 · η 0.80–0.90
Thickness of the plates to be joinedref. 1.3: 3 < t ≤ 10
Sum of all identical welds

5.03–7.66 kg

of ELCOR MR 70 FCW for 10 m of weld

1 pack of 15 kg

Calculated with: η 0.80–0.90: typical value for process 136 · preparation per EN ISO 9692-1 · EN ISO 5817 level C

See the full calculation →
Do I need to preheat?With this product's data: H10
Thickness of the thickest part in the jointmethod B: d from 10 to 90 mm

135 °C

Minimum preheat and minimum interpass temperature

EN 1011-2, annex C, method B · rounded up to 5 °C

✓ Within the range of method B.

Calculated with: HD 10 ml/100 g from this product's class H10 · 136 — gas-shielded flux-cored: 26 V, 220 A, 30 cm/min

See the full calculation →

Field of application

  • Metal-rutile cored wire
  • High deposition rate and therefore deeper penetration
  • Suitable for fillet welds in the flat (PA) and horizontal (PB) positions
  • Excellent impact toughness at low temperatures
  • Shielding gas: CO2
PositionsPA flat PB horizontal-vertical
PolarityDC+
Shielding gasCO2

Classification and approvals

Classification

AWS classE 70 T-9 C J H 8
EN ISO classT 42 4 R C3 H10

Approvals

  • CE, SEPRO
According to the Gedik 2023 catalogue; validity is confirmed with the order

Composition and properties

Chemical composition of the weld metal

C0.04
Mn1.40
Si0.70
Values in mass %.

Mechanical properties

Yield strength (Rp0.2)min. 420 MPa
Tensile strength (Rm)500–640 MPa
Elongation (A5)min. 22 %
Impact energy (KV)min. 47 J (−40 °C)

How to weld

Process

ShieldingRequires shielding gas
FERVEO guidance
By problem
Structural steels