We open on 1 January 2027. Until then we are not accepting registrations or requests.
Datasheetas published in the maker's catalogueCross-referencesacross makers and AWS / EN ISO classesDeliverySpain and PortugalESPTEN
FERVEO
Basket

Catalogue

Clear
Form

We understoodCarbon steels

18 materials

To order · price and lead time in the quote

MIG/MAG wire · Carbon and low-alloy steel 8 materials

ProductStandardRequest
SG 70 S-2 MIGGedik
AWSER70S-2EN ISOG2Ti
AWS ER70S-3
DT-SG 1 MIGDratec
AWSER70S-3EN ISOG 42 4 M21 G2Si1
SG 1 MIGGedik
AWSER70S-3EN ISOG2Si
AWS ER70S-6
DT-SG 2 MIGDratec
AWSER70S-6EN ISOG 42 4 C/M G3Si1
DT-SG 3 MIGDratec
AWSER70S-6EN ISOG 46 4 M21 4Si1
SG 2 MIGGedik
AWSER70S-6EN ISOG3Si 1
SG 3 MIGGedik
AWSER70S-6EN ISOG4Si 1
DT-ZiRo MIGDratec
AWS~ ER70S-2EN ISO-G2Ti

Flux-cored wire · Carbon and low-alloy steel 10 materials

ProductStandardGas / self-shieldedRequest
ELCOR M 70 FCWGedik
AWSE70C-6MEN ISOT 46 4 M M 3
Requires shielding gas
ELCOR B 70 - ARM FCWGedik
AWSE70T-5MEN ISOT 42 A Z B M 3
Requires shielding gas
ELCOR B 70 FCWGedik
AWSE70T-5MJEN ISOT 42 4 B M 3 H5
Requires shielding gas
ELCOR MR 70 FCWGedik
AWSE70T-9CJ H8EN ISOT 42 4 R C3 H10
Requires shielding gas
DT-BF 31 FCWDratec
AWSE70T15-M21A4-CS1-H4, E70T5-C1A4-CS1-H4EN ISOT 46 4 B M 3 H5 / T 42 4 B C 3 H5
Requires shielding gas
DT-MF 10 FCWDratec
AWSE70T15-M21A8-CS1-H4, E70T15-C1A6-CS1-H4EN ISOT 46 6 M M 1 H5 / T 42 5 M C 1 H5
Requires shielding gas
ELCOR R 71 FCWGedik
AWSE71T-1C-JEN ISOT 42 4 P C 1 H5
Requires shielding gas
ELCOR R 71 CM FCWGedik
AWSE71T-1MEN ISOT 46 2 P M 1
Requires shielding gas
DT-RF 14 FCWDratec
AWSE71T1-M21AP5-CS2-DH4, E71T1-C1A4-CS2-DH4EN ISOT 46 4 P M 1 H5 / T 46 2 P C 1 H5
Requires shielding gas
DT-FD2-O FCWDratec
AWSE 71 TGSEN ISOT 42 Z W NO 1 H5
Self-shielded (open arc)
  • ELCOR M 70 FCWGedik

    Standard
    AWSE70C-6MEN ISOT 46 4 M M 3
    Gas / self-shielded
    Requires shielding gas
  • ELCOR B 70 - ARM FCWGedik

    Standard
    AWSE70T-5MEN ISOT 42 A Z B M 3
    Gas / self-shielded
    Requires shielding gas
  • ELCOR B 70 FCWGedik

    Standard
    AWSE70T-5MJEN ISOT 42 4 B M 3 H5
    Gas / self-shielded
    Requires shielding gas
  • ELCOR MR 70 FCWGedik

    Standard
    AWSE70T-9CJ H8EN ISOT 42 4 R C3 H10
    Gas / self-shielded
    Requires shielding gas
  • DT-BF 31 FCWDratec

    Standard
    AWSE70T15-M21A4-CS1-H4, E70T5-C1A4-CS1-H4EN ISOT 46 4 B M 3 H5 / T 42 4 B C 3 H5
    Gas / self-shielded
    Requires shielding gas
  • DT-MF 10 FCWDratec

    Standard
    AWSE70T15-M21A8-CS1-H4, E70T15-C1A6-CS1-H4EN ISOT 46 6 M M 1 H5 / T 42 5 M C 1 H5
    Gas / self-shielded
    Requires shielding gas
  • ELCOR R 71 FCWGedik

    Standard
    AWSE71T-1C-JEN ISOT 42 4 P C 1 H5
    Gas / self-shielded
    Requires shielding gas
  • ELCOR R 71 CM FCWGedik

    Standard
    AWSE71T-1MEN ISOT 46 2 P M 1
    Gas / self-shielded
    Requires shielding gas
  • DT-RF 14 FCWDratec

    Standard
    AWSE71T1-M21AP5-CS2-DH4, E71T1-C1A4-CS2-DH4EN ISOT 46 4 P M 1 H5 / T 46 2 P C 1 H5
    Gas / self-shielded
    Requires shielding gas
  • DT-FD2-O FCWDratec

    Standard
    AWSE 71 TGSEN ISOT 42 Z W NO 1 H5
    Gas / self-shielded
    Self-shielded (open arc)