Catalogue
We understoodCarbon steelsflux-cored wire (FCW)
10 materials
To order · price and lead time in the quote
Flux-cored wire · Carbon and low-alloy steel 10 materials
| Product | Standard | Gas / self-shielded | Request |
|---|---|---|---|
| ELCOR M 70 FCWGedik | AWSE70C-6MEN ISOT 46 4 M M 3 | Requires shielding gas | |
| ELCOR B 70 - ARM FCWGedik | AWSE70T-5MEN ISOT 42 A Z B M 3 | Requires shielding gas | |
| ELCOR B 70 FCWGedik | AWSE70T-5MJEN ISOT 42 4 B M 3 H5 | Requires shielding gas | |
| ELCOR MR 70 FCWGedik | AWSE70T-9CJ H8EN ISOT 42 4 R C3 H10 | Requires shielding gas | |
| DT-BF 31 FCWDratec | AWSE70T15-M21A4-CS1-H4, E70T5-C1A4-CS1-H4EN ISOT 46 4 B M 3 H5 / T 42 4 B C 3 H5 | Requires shielding gas | |
| DT-MF 10 FCWDratec | AWSE70T15-M21A8-CS1-H4, E70T15-C1A6-CS1-H4EN ISOT 46 6 M M 1 H5 / T 42 5 M C 1 H5 | Requires shielding gas | |
| ELCOR R 71 FCWGedik | AWSE71T-1C-JEN ISOT 42 4 P C 1 H5 | Requires shielding gas | |
| ELCOR R 71 CM FCWGedik | AWSE71T-1MEN ISOT 46 2 P M 1 | Requires shielding gas | |
| DT-RF 14 FCWDratec | AWSE71T1-M21AP5-CS2-DH4, E71T1-C1A4-CS2-DH4EN ISOT 46 4 P M 1 H5 / T 46 2 P C 1 H5 | Requires shielding gas | |
| DT-FD2-O FCWDratec | AWSE 71 TGSEN ISOT 42 Z W NO 1 H5 | Self-shielded (open arc) |
ELCOR M 70 FCWGedik
- Standard
- AWSE70C-6MEN ISOT 46 4 M M 3
- Gas / self-shielded
- Requires shielding gas
ELCOR B 70 - ARM FCWGedik
- Standard
- AWSE70T-5MEN ISOT 42 A Z B M 3
- Gas / self-shielded
- Requires shielding gas
ELCOR B 70 FCWGedik
- Standard
- AWSE70T-5MJEN ISOT 42 4 B M 3 H5
- Gas / self-shielded
- Requires shielding gas
ELCOR MR 70 FCWGedik
- Standard
- AWSE70T-9CJ H8EN ISOT 42 4 R C3 H10
- Gas / self-shielded
- Requires shielding gas
DT-BF 31 FCWDratec
- Standard
- AWSE70T15-M21A4-CS1-H4, E70T5-C1A4-CS1-H4EN ISOT 46 4 B M 3 H5 / T 42 4 B C 3 H5
- Gas / self-shielded
- Requires shielding gas
DT-MF 10 FCWDratec
- Standard
- AWSE70T15-M21A8-CS1-H4, E70T15-C1A6-CS1-H4EN ISOT 46 6 M M 1 H5 / T 42 5 M C 1 H5
- Gas / self-shielded
- Requires shielding gas
ELCOR R 71 FCWGedik
- Standard
- AWSE71T-1C-JEN ISOT 42 4 P C 1 H5
- Gas / self-shielded
- Requires shielding gas
ELCOR R 71 CM FCWGedik
- Standard
- AWSE71T-1MEN ISOT 46 2 P M 1
- Gas / self-shielded
- Requires shielding gas
DT-RF 14 FCWDratec
- Standard
- AWSE71T1-M21AP5-CS2-DH4, E71T1-C1A4-CS2-DH4EN ISOT 46 4 P M 1 H5 / T 46 2 P C 1 H5
- Gas / self-shielded
- Requires shielding gas
DT-FD2-O FCWDratec
- Standard
- AWSE 71 TGSEN ISOT 42 Z W NO 1 H5
- Gas / self-shielded
- Self-shielded (open arc)