What an electrode designation means: AWS A5.1 and EN ISO 2560-A

Type the class printed on the box — E7018-1 H4R or E 42 4 B 42 H5 — and we explain every part: strength, impact energy, covering, current, positions and hydrogen. For carbon-steel covered electrodes.

Examples:

AWS A5.1 — carbon steel covered electrodes

SymbolPartWhat it means
EProductCovered electrode for manual metal arc welding.
70Tensile strengthAt least 70 ksi; in AWS A5.1M, 490 MPa (class E49…).
1PositionsAll: flat, horizontal, vertical and overhead.
18Covering and currentBasic, low hydrogen, potassium, with iron powder. Current: AC or DC+.
-1Improved toughnessMeets stricter impact-energy requirements than the class without «-1». E7016-1 and E7018-1: 27 J at −46 °C.
H4Diffusible hydrogenAt most 4 ml per 100 g of deposited weld metal.
RLow moisture absorptionThe covering has passed the AWS A5.1 moisture-absorption test.

AC: alternating current. DC+: direct current, electrode positive. DC−: electrode negative.

In our catalogue, class E7018: 9 electrodes

Each electrode with its full designation, as the maker prints it.

How to read an AWS A5.1 designation

SymbolPartWhat it means
EProductCovered electrode for manual metal arc welding.
60Tensile strengthAt least 60 ksi; in AWS A5.1M, 430 MPa (class E43…).
70Tensile strengthAt least 70 ksi; in AWS A5.1M, 490 MPa (class E49…).
1PositionsAll: flat, horizontal, vertical and overhead.
2PositionsFlat and horizontal fillet.
4PositionsFlat, horizontal, overhead and vertical-down.
10Covering and currentCellulosic, sodium
20, 22Covering and currentIron oxide
11Covering and currentCellulosic, potassium
12Covering and currentRutile (titania), sodium
13Covering and currentRutile (titania), potassium
14, 24Covering and currentRutile (titania) with iron powder
15Covering and currentBasic, low hydrogen, sodium
16Covering and currentBasic, low hydrogen, potassium
27Covering and currentIron oxide with iron powder
18, 28, 48Covering and currentBasic, low hydrogen, potassium, with iron powder
19Covering and currentIron oxide and rutile (titania), potassium
-1Improved toughnessMeets stricter impact-energy requirements than the class without «-1». E7016-1 and E7018-1: 27 J at −46 °C.
H4Diffusible hydrogenAt most 4 ml per 100 g of deposited weld metal.
H8Diffusible hydrogenAt most 8 ml per 100 g of deposited weld metal.
H16Diffusible hydrogenAt most 16 ml per 100 g of deposited weld metal.
RLow moisture absorptionThe covering has passed the AWS A5.1 moisture-absorption test.
MMilitary requirementsClass with additional US military requirements; it carries no H4 or R mark.

Covering, current and positions of the common classes

ClassCovering and currentPositions
E6010Cellulosic, sodium. Current: DC+.All: flat, horizontal, vertical and overhead.
E6011Cellulosic, potassium. Current: AC or DC+.All: flat, horizontal, vertical and overhead.
E6012Rutile (titania), sodium. Current: AC or DC−.All: flat, horizontal, vertical and overhead.
E6013Rutile (titania), potassium. Current: AC, DC+ or DC−.All: flat, horizontal, vertical and overhead.
E6027Iron oxide with iron powder. Current: see the electrode's data sheet; for this class the sources disagree.Flat and horizontal fillet.
E7014Rutile (titania) with iron powder. Current: AC, DC+ or DC−.All: flat, horizontal, vertical and overhead.
E7016Basic, low hydrogen, potassium. Current: AC or DC+.All: flat, horizontal, vertical and overhead.
E7018Basic, low hydrogen, potassium, with iron powder. Current: AC or DC+.All: flat, horizontal, vertical and overhead.
E7024Rutile (titania) with iron powder. Current: AC, DC+ or DC−.Flat and horizontal fillet.

AC: alternating current. DC+: direct current, electrode positive. DC−: electrode negative.

How to read an EN ISO 2560-A designation

Yield, tensile strength and elongation

SymbolWhat it means
35Yield strength ≥ 355 MPa; tensile strength 440–570 MPa; elongation ≥ 22 %.
38Yield strength ≥ 380 MPa; tensile strength 470–600 MPa; elongation ≥ 20 %.
42Yield strength ≥ 420 MPa; tensile strength 500–640 MPa; elongation ≥ 20 %.
46Yield strength ≥ 460 MPa; tensile strength 530–680 MPa; elongation ≥ 20 %.
50Yield strength ≥ 500 MPa; tensile strength 560–720 MPa; elongation ≥ 18 %.

Impact energy

SymbolWhat it means
ZNo impact-energy requirement.
AAt least 47 J average at +20 °C.
0At least 47 J average at 0 °C.
2At least 47 J average at −20 °C.
3At least 47 J average at −30 °C.
4At least 47 J average at −40 °C.
5At least 47 J average at −50 °C.
6At least 47 J average at −60 °C.

Chemical composition of the weld metal

SymbolWhat it means
—No symbol: carbon-manganese steel, Mn ≤ 2.0 %.
MoMn ≤ 1.4 %; Mo 0.3–0.6 %
MnMoMn 1.4–2.0 %; Mo 0.3–0.6 %
1NiMn ≤ 1.4 %; Ni 0.6–1.2 %
Mn1NiMn 1.4–2.0 %; Ni 0.6–1.2 %
2NiMn ≤ 1.4 %; Ni 1.8–2.6 %
Mn2NiMn 1.4–2.0 %; Ni 1.2–2.6 %
3NiMn ≤ 1.4 %; Ni 2.6–3.8 %
1NiMoMn ≤ 1.4 %; Mo 0.3–0.6 %; Ni 0.6–1.2 %
ZAny other agreed composition. «Z» electrodes may not be interchangeable.

Covering

SymbolWhat it means
AAcid
CCellulosic
RRutile
RRRutile, thick
RCRutile-cellulosic
RARutile-acid
RBRutile-basic
BBasic

Efficiency and current

SymbolWhat it means
1Electrode efficiency up to 105 %; alternating and direct current (AC and DC).
2Electrode efficiency up to 105 %; direct current only (DC).
3Electrode efficiency over 105 % up to 125 %; alternating and direct current (AC and DC).
4Electrode efficiency over 105 % up to 125 %; direct current only (DC).
5Electrode efficiency over 125 % up to 160 %; alternating and direct current (AC and DC).
6Electrode efficiency over 125 % up to 160 %; direct current only (DC).
7Electrode efficiency over 160 %; alternating and direct current (AC and DC).
8Electrode efficiency over 160 %; direct current only (DC).

Positions

SymbolWhat it means
1All positions (PA, PB, PC, PD, PE, PF, PG).
2All except vertical-down (PA, PB, PC, PD, PE, PF).
3Flat and horizontal fillet (PA, PB).
4Flat (PA).
5Flat, horizontal fillet and vertical-down (PA, PB, PG).

Diffusible hydrogen

SymbolWhat it means
H5At most 5 ml per 100 g of deposited weld metal.
H10At most 10 ml per 100 g of deposited weld metal.
H15At most 15 ml per 100 g of deposited weld metal.

In EN ISO 2560-A the first five parts are compulsory; efficiency and current, positions and hydrogen are optional.

Basis: EN ISO 2560:2020 (system A) and AWS A5.1/A5.1M. The designation is the maker's declaration; this page explains the symbols and does not replace the standard or the electrode's data sheet.