TITAN K — E 6013
Choose the size
- Ø 2.5 × 350 mm · 5 kg≈ 5 kg
- Ø 3.25 × 350 mm · 5 kg≈ 5 kg
We reply within 1 working day.
How much filler metal do I need?With this product's data: 111 · η 0.55–0.65
6.97–11.14 kg
of TITAN K for 10 m of weld
Calculated with: η 0.55–0.65: typical value for process 111 · preparation per EN ISO 9692-1 · EN ISO 5817 level C
See the full calculation →Field of application
General-purpose electrode, particularly suitable for joining in pipeline construction, vessel and boiler construction and shipbuilding. Particularly suitable for positional welding and root welding and for pipe welds. Finely rippled, well-formed X-ray quality welds with a smooth transition to the parent metal without undercut. The metal transfer is fine-droplet and low-spatter, and the slag is easily removed. The weld metal has high mechanical properties, in particular good low-temperature toughness.
Base metals
| Positions | PA flat PB horizontal-vertical PC horizontal PE overhead PF vertical-up |
|---|---|
| Polarity | DC±/AC |
Classification and approvals
Classification
| AWS class | E 6013 |
|---|---|
| EN ISO class | E 42 2 Z RB 12 |
Approvals
- DB, TÜV, CE
Composition and properties
Chemical composition of the weld metal
| C | 0.08 |
|---|---|
| Mn | 0.60 |
| Ni | 0.80 |
| Si | 0.25 |
Mechanical properties
| Yield strength (Rp0.2) | > 440 MPa |
|---|---|
| Tensile strength (Rm) | 540–610 MPa |
| Elongation (A5) | > 23 % |
| Impact energy (KV) | > 60 J (−30 °C) |
How to weld
Storage
In the original packaging, in dry, ventilated rooms: 5–30 °C, relative humidity < 60 %, up to 2 years.
| Moisture in the covering | More spatter and porosity: redry, above all when low hydrogen content is required. |
|---|---|
| Re-drying | If required: 70–100 °C, 60 min. |
Welding parameters by diameter
| Ø | Length | Current |
|---|---|---|
| 2.5 mm | 350 mm | 80–110 A |
| 3.25 mm | 350 mm | 110–140 A |
| Product | Class | Rm | KV | Availability |
|---|---|---|---|---|
| EGEGedik | E6013 | 470–550 MPa | min. 47 J (0 °C) | To order · price and lead time in the quote |
| ELITGedik | E6013 | 510–610 MPa | min. 47 J (0 °C) | To order · price and lead time in the quote |
| INTERGedik | E6013 | 470–590 MPa | min. 47 J (0 °C) | To order · price and lead time in the quote |
| LOTUSGedik | E6013 | 510–610 MPa | min. 47 J (0 °C) | To order · price and lead time in the quote |
| OPTIMALKjellberg | E6013 | 510–560 MPa | > 60 J (0 °C) | To order · price and lead time in the quote |
Show all (11)
| Product | Class | Rm | KV | Availability |
|---|---|---|---|---|
| PANTERAGedik | E6013 | 510–610 MPa | min. 47 J (0 °C) | To order · price and lead time in the quote |
| PRIMAKjellberg | E6013 | 510–560 MPa | > 60 J (0 °C) | To order · price and lead time in the quote |
| PRIMA BLUEKjellberg | E6013 | 520–600 MPa | > 70 J (−10 °C) | To order · price and lead time in the quote |
| TITANKjellberg | E6013 | 470–530 MPa | > 60 J (20 °C) | To order · price and lead time in the quote |
| TITAN ROTKjellberg | E6013 | 450–550 MPa | > 55 J (0 °C) | To order · price and lead time in the quote |
| TITAN SKjellberg | E6013 | 510–610 MPa | > 60 J (0 °C) | To order · price and lead time in the quote |