Choose the size
- Ø 0.8 mm · BS 300≈ 15 kg
- Ø 0.8 mm · D 300≈ 15 kg
- Ø 1 mm · BS 300≈ 15 kg
- Ø 1 mm · D 300≈ 15 kg
- Ø 1.2 mm · BS 300≈ 15 kg
- Ø 1.2 mm · D 300≈ 15 kg
- Ø 1.6 mm · BS 300≈ 15 kg
- Ø 1.6 mm · D 300≈ 15 kg
To order · price and lead time in the quote
We reply within 1 working day.
How much filler metal do I need?With this product's data: 135 · η 0.92–0.98
Thickness of the plates to be joinedref. 1.3: 3 < t ≤ 10
Sum of all identical welds
4.62–6.66 kg
of SG 80 S-D2 MIG for 10 m of weld
1 pack of 15 kg
Calculated with: η 0.92–0.98: typical value for process 135 · preparation per EN ISO 9692-1 · EN ISO 5817 level C
See the full calculation →Field of application
- Copper coated for GMAW and TIG welding in boiler pressure vessel, pipework and crane construction as well as in structural steel engineering
- High quality, very tough deposit of high crack resistance and non-aging
- Recommended for service in temperature range -45°C (TIG) or -40 °C (GMAW) to +550 °C.
- Good copper bonding with low total copper content
- Very good welding and flow characteristics
- Preheating interpass and postweld heat treatment as required by base metal
- Shielding gases: MAG; Ar+CO2 mix gases, TIG; pure Ar gas can be used
Base metals
S355J2G3L320-L415NBL320MB-L415MBP255G1THP235GH-P355GH16Mo317MnMoV6-420MnMoNi5-520MnMoNi4-5GE240-GE30022Mo4S255N-S460NP255NH-P460 NH
| Positions | PA flat PB horizontal-vertical PC horizontal PD horizontal-overhead PE overhead PF vertical-up PG vertical-down |
|---|---|
| Polarity | DC+ |
| Shielding gas | Ar + CO2 |
Classification and approvals
Classification
| AWS class | ER 80 S-D2 |
|---|---|
| EN ISO class | G 4Mo |
Approvals
- CE, SEPRO
According to the Gedik 2023 catalogue; validity is confirmed with the order
Composition and properties
Chemical composition of the wire
| C | 0.10 |
|---|---|
| Mn | 1.80 |
| Mo | 0.50 |
| Si | 0.65 |
Values in mass %.
Mechanical properties
| Yield strength (Rp0.2) | min. 470 MPa |
|---|---|
| Tensile strength (Rm) | 550–680 MPa |
| Elongation (A5) | min. 20 % |
| Impact energy (KV) | min. 47 J (−30 °C) |
How to weld
Process
| Shielding | Requires shielding gas |
|---|
Treatment and preparation
| Pre-heating | as required by the base metal |
|---|---|
| Interpass temperature | as required by the base metal |
| Post-weld heat treatment | as required by the base metal |
FERVEO guidance
By problem
Structural steels