FERVEO
Log in / Create accountES
Heat-resistant Cr-Mo steels

FERVEO CMO 1 FCW

flux-cored wire (FCW)Catalogue only
also as: solid wireTIG rod
AWS class
E81 T1-B2C
EN ISO class
T CrMo1 R C 2
Tensile strength (Rm)
550–690 MPa

Classification

AWS classE81 T1-B2C
EN ISO classT CrMo1 R C 2

Purpose

  • CO₂-shielded flux-cored wire, 1.2% Cr–0.5% Mo (AWS E81T1-B2C, EN ISO T CrMo1 R C 2) — welding heat-resistant Cr-Mo steels in a higher-productivity flux-cored format.

Why it works

The same Cr-Mo alloy as the FERVEO CMO 1 family, in gas-shielded flux-cored wire format — higher deposition productivity than a covered electrode, for semi-automatic welding of Cr-Mo boilers and piping in higher-volume fabrication.

Fields of application

  • Cr-Mo steel boilers, piping, and castings in higher-volume fabrication, semi-automatic format.

Chemical composition

ElementTypical, %
C0.06
Cr1.2
Mn1.2
Mo0.5
Si0.5

Mechanical properties

Tensile strength (Rm)550–690 MPa
Yield strength (Rp0.2)460 MPa

Process

PolarityDC+
Shielding gasC1
PositionsPAflatPBhorizontal-verticalPChorizontalPDhorizontal-overheadPEoverheadPFvertical-up
Requires shielding gasRequires shielding gas
Heat treatment680°C / 1h

Base metals

DIN: 13 CrMo 4424 CrMo 5Cast Steels: GS 17CrMo55GS 22CrMo54G17CrMo5-5G22CrMo5-4EN: 13 CrMo 4-5G 17 CrMo 5-5G 22 CrMo 5-4ASTM: A 182A 387A217A 387 Gr. 11-12

Advantages

  • Semi-automatic flux-cored format — higher deposition productivity than a covered electrode for the same CrMo1 grade.
  • Same Cr-Mo alloy grade as the FERVEO CMO 1 electrode family — consistent in-service behavior across processes.

Limitations

  • Needs shielding-gas equipment — not self-shielded, unlike other FERVEO hardfacing families.