Gedik · Low-alloy steels
TEMPO B 48 — E 7018-G H4
covered electrode · stick electrodebasic coating
Choose the size
- Ø 2.5 × 350 mm≈ 5 kg
- Ø 3.2 × 350 mm≈ 5 kg
- Ø 4 × 350 mm≈ 5 kg
To order · price and lead time in the quote
We reply within 1 working day.
How much filler metal do I need?With this product's data: 111 · η 0.63
Thickness of the plates to be joinedref. 1.3: 3 < t ≤ 10
Sum of all identical welds
7.19–9.72 kg
of TEMPO B 48 for 10 m of weld
2 packs of ≈ 5 kg
Calculated with: η 0.63 — from the datasheet (recovery 120 %, Ø 2.5 × 350 mm) · preparation per EN ISO 9692-1 · EN ISO 5817 level C
See the full calculation →Do I need to preheat?With this product's data: H5
Thickness of the thickest part in the jointmethod B: d from 10 to 90 mm
100 °C
Minimum preheat and minimum interpass temperature
EN 1011-2, annex C, method B · rounded up to 5 °C
✓ Within the range of method B.
Calculated with: HD 5 ml/100 g from this product's class H5 · 111 — basic electrode: 24 V, 160 A, 15 cm/min
See the full calculation →Field of application
- This is AC/DC basic-coated electrode that has a weld metal recovery of 120% which can be used at all welding positions except for the vertical down position
- Usable with short arc in (-) pole for root pass welding with excellent penetration, especially at vertical-up position
- Weld deposit with high low temperature toughness
- Re-drying: 300-350°C / 2h
Base metals
EN 10205:
S355J2G3S355JRS355JOS355J2G4S355K2G3S355K2G4
ASTM:
A 572 Gr.50A709Gr.50A678Gr.50A633Gr.D
API 5L:
ABX42X46X52X56X60
| Positions | PA flat PB horizontal-vertical PC horizontal PD horizontal-overhead PE overhead PF vertical-up |
|---|---|
| Polarity | DC±/AC |
Classification and approvals
Classification
| AWS class | E 7018-G H4 |
|---|---|
| EN ISO class | E 42 6 1 Ni B 32 H5 |
Approvals
- TSE, CE, ABS, SEPRO, BV
According to the Gedik 2023 catalogue; validity is confirmed with the order
Composition and properties
Chemical composition of the weld metal
| C | 0.06 |
|---|---|
| Mn | 1.00 |
| Ni | 0.80 |
| Si | 0.50 |
Values in mass %.
Mechanical properties
| Yield strength (Rp0.2) | min. 460 MPa |
|---|---|
| Tensile strength (Rm) | 530–640 MPa |
| Elongation (A5) | min. 22 % |
| Impact energy (KV) | min. 47 J (−60 °C) |
How to weld
Process
| Recovery | 120 % |
|---|
Treatment and preparation
| Re-drying | 300–350 °C / 2 h |
|---|
Welding parameters by diameter
| Ø | Length | Current |
|---|---|---|
| 2.5 mm | 350 mm | 60–100 A |
| 3.2 mm | 350 mm | 80–130 A |
| 4 mm | 350 mm | 120–180 A |
FERVEO guidance
By problem
Structural steels