Download PDF
← Technical datasheet
Gedik · Creep-resisting Cr-Mo steels
FERVEO

SG CrMo 1 Si MIG — ER 80 S-G

Technical datasheet · solid wire · Ø 0.8 – 1.6 mm
FT-SG-CRMO-1-SI-MIG-EN
rev. 2 · 2026-11-21
page 1 / 2
Type
solid wire
Standard
ER 80 S-G
Diameters
Ø 0.8 – 1.6 mm
Sizes and packaging
Ø
Packaging
Code
0.8 mm
BS 300
GDK-3010201969
0.8 mm
D 300
GDK-3010201992
1 mm
BS 300
GDK-3010201971
1 mm
D 300
GDK-3010201994
1.2 mm
BS 300
GDK-3010201973
1.2 mm
D 300
GDK-3010201996
1.6 mm
BS 300
GDK-3010201974
1.6 mm
D 300
GDK-3010201998
Application
  • Used for the welding of high heat resisting. Cr-Mo alloyed steels which are used for the production of boilers tubes and pipes and nitrided steels
  • Weld metal is resistant to temperatures up to +570°C
  • Shielding gases: MAG; Ar+CO2 and Ar+O2 mix gases, TIG; pure Ar gas can be used
Classification
AWS class
ER 80 S-G
EN ISO class
G CrMo 1 Si
Approvals

CE, SEPRO

Validity is confirmed with the order

Chemical composition of the wire
C
Cr
Mn
Mo
Si
0.10
1.20
1.00
0.50
0.60
Values in mass %.
Base metals

13CrMo4-5 · 15CrMo5 · 42CrMo4 · 16CrMoV4 · 25CrMo4 · 24CrMo5 · G22CrMo5-4 · G17CrMo5-5

QR code for the current version of this datasheet
FERVEO IBERICA, S.L.U. · NIF B05613559 · Avda. del Tomillar, 70, 29631 Benalmádena (Málaga) · Registered in the Registro Mercantil de Málaga, sheet MA-201214 · info@ferveo.eu · www.ferveo.eu · FT-SG-CRMO-1-SI-MIG-EN · rev. 2 · page 1 / 2

Typical values, not guaranteed: this document is not a declaration of performance and does not replace the manufacturer's official documentation or the applicable WPS.

Prepared by FERVEO from the Gedik 2023 catalogue

Gedik · Creep-resisting Cr-Mo steels
FERVEO

SG CrMo 1 Si MIG — ER 80 S-G

Technical datasheet · solid wire · Ø 0.8 – 1.6 mm
FT-SG-CRMO-1-SI-MIG-EN
rev. 2 · 2026-11-21
page 2 / 2
Mechanical properties
after heat treatment: 680 °C / 1 h / 300 °C (air)
Yield strength (Rp0.2)
min. 470 MPa
Tensile strength (Rm)
550–670 MPa
Elongation (A5)
min. 20 %
Impact energy (KV)
min. 47 J (20 °C)
Process
Polarity
DC+
Shielding gas
Ar + CO2, Ar + O2
Positions
PA flat · PB horizontal-vertical · PC horizontal · PD horizontal-overhead · PE overhead · PF vertical-up · PG vertical-down
Shielding
Requires shielding gas
QR code for the current version of this datasheet
FERVEO IBERICA, S.L.U. · NIF B05613559 · Avda. del Tomillar, 70, 29631 Benalmádena (Málaga) · Registered in the Registro Mercantil de Málaga, sheet MA-201214 · info@ferveo.eu · www.ferveo.eu · FT-SG-CRMO-1-SI-MIG-EN · rev. 2 · page 2 / 2

Typical values, not guaranteed: this document is not a declaration of performance and does not replace the manufacturer's official documentation or the applicable WPS.

Prepared by FERVEO from the Gedik 2023 catalogue