Download PDF
← Technical datasheet
Gedik · Hardfacing
FERVEO

HARDCOR 60 G FCW — T Fe 8

Technical datasheet · flux-cored wire (FCW) · Ø 1.2 – 1.6 mm
FT-HARDCOR-60-G-FCW-EN
rev. 2 · 2026-11-21
page 1 / 1
Type
flux-cored wire (FCW)
Standard
T Fe 8
Diameters
Ø 1.2 – 1.6 mm
Sizes and packaging
Ø
Current
Voltage
Stick-out
Packaging
Code
1.2 mm
170–200 A
27–30 V
25–30 mm
15 kg
GDK-3030500406
1.6 mm
180–200 A
26–30 V
30–35 mm
15 kg
GDK-3030500408
Application
  • Metal type flux-cored wire.
  • Examples of applications; cutting tools, blades of shears, rolls for cold rolling mills, roller table roll, forging die, jaw crusher, breaker hammer, beating arm, clod crusher, ripper tooth, scarifies, mixer part, mixer bottom, blast furnace valve, top gas valve, sea dredger slide guide, shackle, mixer parts.
  • Used for resistance to abrasion, impact resistance and heat resistance.
  • The weld metal is air-hardening and can usually only be worked by grinding. Preheating up to 200 to 300°C is recommended.
  • Shielding Gas: CO2 (M21)
Classification
EN 14700 class
T Fe 8
DIN 8555 class
MF 6 GF 60 GP
Chemical composition of the weld metal
C
V
Cr
Fe
Mn
Mo
Si
0.60
0.20
5.50
balance
0.60
0.25
0.60
Values in mass %.
Hardness
as welded
57–62 HRC
Process
Polarity
DC+
Shielding gas
CO2, M21
Shielding
Requires shielding gas
Treatment and preparation
Pre-heating
200–300 °C
QR code for the current version of this datasheet
FERVEO IBERICA, S.L.U. · NIF B05613559 · Avda. del Tomillar, 70, 29631 Benalmádena (Málaga) · Registered in the Registro Mercantil de Málaga, sheet MA-201214 · info@ferveo.eu · www.ferveo.eu · FT-HARDCOR-60-G-FCW-EN · rev. 2 · page 1 / 1

Typical values, not guaranteed: this document is not a declaration of performance and does not replace the manufacturer's official documentation or the applicable WPS.

Prepared by FERVEO from the Gedik 2023 catalogue