Gedik · Hardfacing
ELHARD 650 — E Fe 6
covered electrode · stick electrode
Choose the size
- Ø 3.2 × 350 mm≈ 5 kg
- Ø 4 × 450 mm≈ 5 kg
- Ø 5 × 450 mm≈ 5 kg
To order · price and lead time in the quote
We reply within 1 working day.
Field of application
- For hardfacing in the earthmoving industry and on wear parts of grinding mills, etc.
- Can be applied directly; if 3 or more layers are to be deposited, apply a buffer layer first, depending on the material grade (ELHARD 63, ELHARD 250, ELOX R 307 or ELHARD 14 Mn)
- For hardenable steels, the preheating temperature is 100 °C to 300 °C
- Redrying of the electrodes before use at 300 °C to 350 °C for at least 2 h is recommended
| Polarity | DC+ |
|---|
Classification and approvals
Classification
| EN 14700 class | E Fe 6 |
|---|---|
| DIN 8555 class | E6-UM-60 |
Approvals
- SEPRO
According to the Gedik 2023 catalogue; validity is confirmed with the order
Composition and properties
Chemical composition of the weld metal
| C | 0.55 |
|---|---|
| Cr | 6.80 |
| Mn | 1.35 |
| Mo | 1.20 |
| Nb | 0.60 |
| Si | 0.75 |
Values in mass %.
Hardness
- 56–59 HRC
How to weld
Treatment and preparation
| Re-drying | 300 °C / 2 h |
|---|---|
| Pre-heating | 100–300 °C, for hardenable steels |
Welding parameters by diameter
| Ø | Length | Current |
|---|---|---|
| 3.2 mm | 350 mm | 100–140 A |
| 4 mm | 450 mm | 140–180 A |
| 5 mm | 450 mm | 180–230 A |
FERVEO guidance
By problem
Wear-resistant hardfacing