DT-DUR 67 FCW — T Fe 16

Technical datasheet · flux-cored wire (FCW) · Ø 1.6 – 2.8 mm
FT-DT-DUR-67-FCW-EN
rev. 2 · 2026-11-21
page 1 / 1
Type
flux-cored wire (FCW)
Standard
T Fe 16
Diameters
Ø 1.6 – 2.8 mm
Sizes and packaging
Ø
Current
Voltage
Packaging
Code
1.6 mm
160–260 A
20–28 V
K300 15–20 kg
DRT-1529-16
2 mm
240–280 A
22–26 V
K300 15–20 kg
DRT-1529-20
2.4 mm
280–340 A
25–29 V
K300 15–20 kg
DRT-1529-24
2.8 mm
320–400 A
26–30 V
K300 15–20 kg
DRT-1529-28
Application

Flux-cored wire highly alloyed with C, Cr and V, with high scratch hardness. Owing to the high percentage of alloying constituents, DT-DUR 67 is suitable for extremely hard overlays on parts subject to extremely severe abrasive mineral wear. Owing to the alloy composition, the wear resistance is retained even at elevated working temperatures. No more than two layers should be applied; screw conveyors, fan blades, agitators, clinker crushers, mixer blades, cement and concrete pumps, fire grates, gravel and washing plants, etc.

Classification
EN 14700 class
T Fe 16
DIN 8555 class
MF 10 - 65 - G Z
Chemical composition of the wire
C
V
Cr
Si
5.00
10.0
22.0
1.00
Values in mass %.
Hardness
guide values
64–67 HRC
QR code for the current version of this datasheet
FERVEO IBERICA, S.L.U. · NIF B05613559 · Avda. del Tomillar, 70, 29631 Benalmádena (Málaga) · Registered in the Registro Mercantil de Málaga, sheet MA-201214 · info@ferveo.eu · www.ferveo.eu · FT-DT-DUR-67-FCW-EN · rev. 2 · page 1 / 1

Typical values, not guaranteed: this document is not a declaration of performance and does not replace the manufacturer's official documentation or the applicable WPS.

Prepared by FERVEO from the Dratec 2025 catalogue