Kjellberg · Carbon steels
TRUMPF — E 6027
covered electrode · stick electrode
Choose the size
- Ø 3.25 × 450 mm · 6 kg≈ 6 kg
- Ø 4 × 450 mm · 6 kg≈ 6 kg
- Ø 5 × 450 mm · 6 kg≈ 6 kg
To order · price and lead time in the quote
We reply within 1 working day.
How much filler metal do I need?With this product's data: 111 · η 0.55–0.65
Thickness of the plates to be joinedref. 1.3: 3 < t ≤ 10
Sum of all identical welds
6.97–11.14 kg
of TRUMPF for 10 m of weld
2 packs of 6 kg
Calculated with: η 0.55–0.65: typical value for process 111 · preparation per EN ISO 9692-1 · EN ISO 5817 level C
See the full calculation →Field of application
Covered electrode with very high welding speed for joining in mechanical engineering, steel construction and shipbuilding, particularly suitable for capping runs. Fine-droplet transfer, flat to slightly concave fillet welds, easy slag removal.
Base metals
Non-alloy structural steels: S235 to S275Shipbuilding steels: A, B, DPressure vessel steels: P195 to P275Pipeline steels: L210 to L245Cast steels: GE200, GE240, GP240, G20MoReinforcing steels: BSt 420
| Positions | PA flat PB horizontal-vertical |
|---|---|
| Polarity | DC−/AC |
Classification and approvals
Classification
| AWS class | E 6027 |
|---|---|
| EN ISO class | E 35 0 A 13 |
Approvals
- DB, CE
According to the Kjellberg 2019 catalogue; validity is confirmed with the order
Composition and properties
Chemical composition of the weld metal
| C | 0.10 |
|---|---|
| Mn | 0.50 |
| Si | 0.10 |
Values in mass %.
Mechanical properties
| Yield strength (Rp0.2) | > 370 MPa |
|---|---|
| Tensile strength (Rm) | 440–510 MPa |
| Elongation (A5) | > 22 % |
| Impact energy (KV) | > 70 J (0 °C) |
How to weld
Storage
In the original packaging, in dry, ventilated rooms: 5–30 °C, relative humidity < 60 %, up to 2 years.
| Moisture in the covering | More spatter and porosity: redry, above all when low hydrogen content is required. |
|---|---|
| Re-drying | If required: 70–100 °C, 60 min. |
According to the Kjellberg 2019 catalogue
Welding parameters by diameter
| Ø | Length | Current |
|---|---|---|
| 3.25 mm | 450 mm | 110–140 A |
| 4 mm | 450 mm | 130–170 A |
| 5 mm | 450 mm | 170–210 A |
FERVEO guidance
By problem