Download PDF
← Technical datasheet
Gedik · Carbon steels
FERVEO

SG 70 S-2 MIG — ER 70 S-2

Technical datasheet · solid wire · Ø 0.8 – 1.6 mm
FT-SG-70-S-2-MIG-EN
rev. 2 · 2026-11-21
page 1 / 2
Type
solid wire
Standard
ER 70 S-2
Diameters
Ø 0.8 – 1.6 mm
Sizes and packaging
Ø
Packaging
Code
0.8 mm
BS 300
GDK-3010202833
0.8 mm
D 300
GDK-3010202856
1 mm
BS 300
GDK-3010202835
1 mm
D 300
GDK-3010202858
1.2 mm
BS 300
GDK-3010202837
1.2 mm
D 300
GDK-3010202860
1.6 mm
BS 300
GDK-3010202838
1.6 mm
D 300
GDK-3010202862
Application
  • Pipes, boilers and machine structures of non-alloy and low-alloy materials; thin materials and root runs
  • Deoxidised with Ti, Al and Zr, so preferred especially for rusty, dirty, primed and painted steels
  • Shielding gas: pure Ar for TIG welding, Ar + CO2 mixtures for MAG welding
Classification
AWS class
ER 70 S-2
EN ISO class
G2Ti
Approvals

TSE, CE, SEPRO

Validity is confirmed with the order

Chemical composition of the wire
C
Al
Mn
Si
Ti
Zr
0.05
0.11
1.10
0.55
0.12
0.07
Values in mass %.
Base metals

S235J2G3-S355J2G3 · P235T2-P355T2 · L210NB-L290NB · L290MB-L360MB · P235G1TH · P255G1TH · P235GH · P355GH · S235JRS1-S235J4S · S315G1S-S355G3S · P255NH-P355NH · S255N-S420N · GE200-GE300

QR code for the current version of this datasheet
FERVEO IBERICA, S.L.U. · NIF B05613559 · Avda. del Tomillar, 70, 29631 Benalmádena (Málaga) · Registered in the Registro Mercantil de Málaga, sheet MA-201214 · info@ferveo.eu · www.ferveo.eu · FT-SG-70-S-2-MIG-EN · rev. 2 · page 1 / 2

Typical values, not guaranteed: this document is not a declaration of performance and does not replace the manufacturer's official documentation or the applicable WPS.

Prepared by FERVEO from the Gedik 2023 catalogue

Gedik · Carbon steels
FERVEO

SG 70 S-2 MIG — ER 70 S-2

Technical datasheet · solid wire · Ø 0.8 – 1.6 mm
FT-SG-70-S-2-MIG-EN
rev. 2 · 2026-11-21
page 2 / 2
Mechanical properties
Yield strength (Rp0.2)
min. 400 MPa
Tensile strength (Rm)
min. 480 MPa
Elongation (A5)
min. 22 %
Impact energy (KV)
min. 47 J (−30 °C)
Process
Polarity
DC+
Shielding gas
Ar + CO2
Positions
PA flat · PB horizontal-vertical · PC horizontal · PD horizontal-overhead · PE overhead · PF vertical-up · PG vertical-down
Shielding
Requires shielding gas
QR code for the current version of this datasheet
FERVEO IBERICA, S.L.U. · NIF B05613559 · Avda. del Tomillar, 70, 29631 Benalmádena (Málaga) · Registered in the Registro Mercantil de Málaga, sheet MA-201214 · info@ferveo.eu · www.ferveo.eu · FT-SG-70-S-2-MIG-EN · rev. 2 · page 2 / 2

Typical values, not guaranteed: this document is not a declaration of performance and does not replace the manufacturer's official documentation or the applicable WPS.

Prepared by FERVEO from the Gedik 2023 catalogue