Gedik · Hardfacing

HARDCOR 600 GS FCW — T Fe 6
Technical datasheet · flux-cored wire (FCW) · Ø 1.2 – 1.6 mm
FT-HARDCOR-600-GS-FCW-EN
rev. 2 · 2026-11-21
page 1 / 1
rev. 2 · 2026-11-21
page 1 / 1
Type
flux-cored wire (FCW)
Standard
T Fe 6
Diameters
Ø 1.2 – 1.6 mm
Sizes and packaging
Ø
Current
Voltage
Stick-out
Packaging
Code
1.2 mm
170–200 A
27–30 V
25.0–30.0 mm
15 kg
GDK-3030500018
1.6 mm
180–220 A
26–31 V
25.0–30.0 mm
15 kg
GDK-3030500019
Application
- Used in hardfacing welding of pieces exposed to high impact and abrasion wear
- Weld metal microstructure is martensitic and has excellent resistance to friction metal to metal
- This wire can also be used as a filling for cutting edge welding
- Cracking does not observed
- Because of the rutile character there is no spatter during welding, weld metal seam is perfect
- Shielding Gas: CO2
Classification
EN 14700 class
T Fe 6
DIN 8555 class
MF 6 GF 60 GR
Approvals
SEPRO
Validity is confirmed with the order
Chemical composition of the weld metal
C
Cr
Mn
Mo
Nb
Si
0.60
8.20
0.65
0.20
0.15
0.60
Values in mass %.
Hardness
as welded
56 HRC
Process
Polarity
DC+
Shielding gas
CO2
Shielding
Requires shielding gas
FERVEO IBERICA, S.L.U. · NIF B05613559 · Avda. del Tomillar, 70, 29631 Benalmádena (Málaga) · Registered in the Registro Mercantil de Málaga, sheet MA-201214 · info@ferveo.eu · www.ferveo.eu · FT-HARDCOR-600-GS-FCW-EN · rev. 2 · page 1 / 1
Typical values, not guaranteed: this document is not a declaration of performance and does not replace the manufacturer's official documentation or the applicable WPS.
Prepared by FERVEO from the Gedik 2023 catalogue