Download PDF
← Technical datasheet
Gedik · Hardfacing
FERVEO

HARDCOR 50 G FCW — T Z Fe 8

Technical datasheet · flux-cored wire (FCW) · Ø 1.2 mm
FT-HARDCOR-50-G-FCW-EN
rev. 2 · 2026-11-21
page 1 / 1
Type
flux-cored wire (FCW)
Standard
T Z Fe 8
Diameters
Ø 1.2 mm
Sizes and packaging
Ø
Current
Voltage
Stick-out
Packaging
Code
1.2 mm
170–200 A
27–30 V
15–25 mm
15 kg
GDK-6031100370
Application
  • Applicability in hardfacing for protection against wear of steels working at temperatures up to 650°C
  • Existence of high amounts of Cr, Co, Mo alloys in weld metal
  • High resistance to cracking
  • Oxidation- and creep-resistant behaviours at high temperatures
  • High resistance against sliding wear of metallic object
  • High resistance to thermal shock
  • Shielding Gas: M 13 (Ar+1%O2)
Classification
EN 14700 class
T Z Fe 8
DIN 8555 class
MF 3-50-CKTZW
Approvals

SEPRO

Validity is confirmed with the order

Chemical composition of the weld metal
C
Co
Cr
Fe
Mn
Mo
Ni
Si
0.10
14.0
15.0
balance
0.40
3.20
present
0.70
Values in mass %.
Mechanical properties
Service temperature
max. 650 °C
Hardness
as welded
48–50 HRC
Hardness after work hardening
53 HRC
Process
Polarity
DC+
Shielding gas
Ar + 1% O2, M 13
Shielding
Requires shielding gas
QR code for the current version of this datasheet
FERVEO IBERICA, S.L.U. · NIF B05613559 · Avda. del Tomillar, 70, 29631 Benalmádena (Málaga) · Registered in the Registro Mercantil de Málaga, sheet MA-201214 · info@ferveo.eu · www.ferveo.eu · FT-HARDCOR-50-G-FCW-EN · rev. 2 · page 1 / 1

Typical values, not guaranteed: this document is not a declaration of performance and does not replace the manufacturer's official documentation or the applicable WPS.

Prepared by FERVEO from the Gedik 2023 catalogue